Please use this identifier to cite or link to this item:
https://hdl.handle.net/10953.1/8940
Title: | Análisis de las medidas de refuerzo y reacondicionamiento sísmico en las estructuras de edificios dañados por los terremotos de Lorca |
Authors: | Espadas-Priego, Álvaro |
metadata.dc.contributor.advisor: | Donaire-Ávila, Jesús |
metadata.dc.contributor.other: | Universidad de Jaén. Ingeniería Mecánica y Minera |
Abstract: | [ES]Los terremotos de Lorca de mayo de 2011, catalogados como impulsivos cerca de falla, produjeron diferentes daños en la estructura de los edificios, sobre todo en planta baja. En este TFG se estudia una estructura de un edificio de 4 plantas, formada por pórticos de hormigón armado con vigas planas. Se analiza la carga sísmica, debido tanto a la acción de proyecto como a la real del terremoto de Lorca. Se determinan tanto las acciones en pilares de planta baja como los desplazamientos de la estructura para obtener su nivel de ductilidad. A partir de los resultados obtenidos en los cálculos se plantea como medida de reacondicionamiento el recrecido de hormigón armado en pilares de planta baja con el objetivo de mejorar resistencia y ductilidad. Finalmente se lleva a cabo el análisis de la estructura reacondicionada, comparando los resultados antes y después de aplicar el refuerzo, dictaminando su bondad respecto a la demanda de resistencia y desplazamiento a la que se ve sometida la estructura. [EN]The Lorca earthquakes of May of 2011 (pulse-like ground motions) led to different damages for the structure of the buildings, mainly in ground floor. This TFG is based on the 4-story reinforced concrete building with shallow beams. A seismic analysis is carried out taking into account both the project and the real seismic action from the Lorca earthquakes. Forces are determined for columns of the ground floor as well as the displacements of the structure to obtain the story ductility level. Once the results are obtained from the calculations, the reinforced concrete jacketed is put forward as a measure to retrofit the columns of the structure on ground floor to improve both the strength and the ductility. Finally, the analysis of the retrofitted structure is carried out, comparing the results before and after applying the strenthening. The goodness of the retrofitted structure is discussed in terms of strength and ductility. |
Issue Date: | 26-Sep-2017 |
metadata.dc.rights: | info:eu-repo/semantics/openAccess |
Appears in Collections: | Grado en Ingeniería de Recursos Energéticos (E.P.S. Linares) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
TFG.AlvaroEspadasPriego.pdf | 4,52 MB | Adobe PDF | ![]() View/Open |
This item is protected by original copyright |
Items in TAUJA are protected by copyright, with all rights reserved, unless otherwise indicated.